E-Cooler BTM / BCS

E-Cooler

The fast growing electrification of mobility – particularly in public transport – requires high-performance mobile energy storage systems that enhance travel comfort.
With E-Cooler Spheros has introduced a range of battery temperature management models with a maximum cooling capacity of 10 kW, offering an optimal solution for a wide range of applications. Depending on the requirement, the E-Cooler protects the battery from overheating during charging and discharging, cools it while driving at higher outside temperatures and heavy loads.
An additional heating function even warms up the sensitive batteries if necessary to ensure the optimal temperature range for the charging cycle.

INFORMACIONES IMPORTANTES

BCS : Standalone solution with active or passive cooling circuit in the basic version

  • Integrated control unit with intelligent working algorithm
  • Integrated water sensor for controlling the unit to reach and keep the desired water outlet temperature
  • CAN-bus connection to the vehicle
  • 24 V fan, 600 V EDC
  • Modular design enables individual adaptation in terms of performance, switch-off temperature

Low life-cycle-costs

  • Energy-optimized operation of the BTMS extends range of the bus
  • -> Control of compressor and fan according to the required minimum demand
  • -> Device always starts with passive cooling to save energy and is automatically switched to active cooling or heating mode if required
  • Strong passive cooling performance
  • -> 10kW at dT of 15K
  • -> 3KW at dT of 5K
  • The extended use of passive cooling will increase the service life of the EDC
  • Pure 24 V technology at E-Cooler 50 version: easy service

Safety

  • Safe operation of the battery is guaranteed within a narrowly defined temperature range
  • -> The way the battery is conditioned therefore has an effect on the vehicle's range

DATOS TÉCNICOS

  E-Cooler 100 BTM E-Cooler 100T BTM E-Cooler 50 BCS E-Cooler 100 BCS
Maximum cooling capacity (kW) at:
outside temperature (°C)
of coolant outlet (°C)
of coolant flow (l/h)
10 (9)
44 (approx. 50)
35
approx. 3,000
10 (12)
55 (44)
35
approx. 3,000
6 (approx. 5kW)
44
35 (25°C)
1,000
10
44
35
2,000
Maximum power consumption
(compressor / fan)
compressor 10,5A at 800V
fan 21A at 28.5V
compressor 15A at 800V
fan 31A at 28.5V
75A 5A / 18A
Maximum weight depending on design (kg)
w/o coolant-carrying components
75 115 60 55
Voltage (compressor / fan) V 650 / 24 650 / 24 24 / 24 650 / 24
Dimensions L x W x H (mm) appr. 1,200 x 511 x 350* appr. 1,700 x 511 x 350* 980 x 670 x 310 780 x 400 x 375
Coolant
Filling capacity (kg)
R134a
approx. 1.5
R134a
approx. 1.7
R134a R134a
active and passive cooling, heating
water circuit,
water pump,
valves, expansion tank
active and passive cooling, heating
water circuit,
water pump,
valves, expansion tank
active and passive cooling,
control
cooling only,
expansion tank, water pump, control
SOP Q4/2024 on demand SOP Q4/2023

Contains flourinated greenhouse gases

Dimensions depend on the final power requirement and the outside temperature

Weight depend on design

DOWNLOAD CATÁLOGO